A fuel containment liner is an impermeable, fuel-resistant liner that holds oil or fuel and keeps it off the ground. It can line a pit, a temporary tank or a bermed area, so that petroleum products do not reach the soil or groundwater.
This article explains how these liners are used, which material we recommend, and what we built for a recent oil storage project. A customer in a country neighboring Russia needed large liners for the temporary storage of crude oil, petroleum products and oily waste. We produced the coated fabric, fabricated the liners and packed complete kits, so the customer could deploy them on arrival.
For general containment covers made to size, see our containment tarps.
I. What Is a Fuel Containment Liner?
A fuel containment liner is a flexible, welded sheet that forms a liquid-tight basin for oil or fuel. It is used where a rigid steel tank is not practical, for example at remote sites, for short projects, or when storage has to be set up quickly.
Typical uses include:
- Lining an earthen pit for temporary oil or fuel storage.
- Lining a frame tank that can be assembled and taken down.
- Lining a berm or dike around tanks, drums or equipment to catch leaks.
Primary vs Secondary Containment
The same type of liner can play two different roles:
| Role | What the liner does | Example |
|---|---|---|
| Primary containment | Holds the oil or fuel directly | A lined pit or a lined frame tank used for storage |
| Secondary containment | Catches oil or fuel if the primary container leaks | A secondary containment liner under or around a tank |
The liners in our project were used for primary storage: the oil was stored directly inside them.
II. Which Material Should You Use for an Oil Storage Liner?
Fuel containment liners are made from several materials, including polyethylene geomembranes and coated fabrics. For prefabricated oil storage liners that are shipped to site and deployed, we recommend an oil-resistant PVC-coated polyester fabric. It is the material we used in this project.
| What the project needs | How our oil-resistant PVC-coated polyester delivers it |
|---|---|
| Resistance to oil and fuel | Oil-resistant, fuel-resistant PVC coating with a PVDF-treated surface, resistant to crude oil, gasoline and lubricating oils |
| Strength for large liners | 1000D × 1000D polyester base fabric; tensile strength 2730 / 1900 N/5cm |
| Liquid-tight seams | Weldable by hot air; triple-welded seams reach at least 90% of the base fabric strength |
| Outdoor use | UV resistant; service temperature −30 °C to +70 °C |
| Fast deployment | Fully prefabricated in our factory, folded and shipped as a ready-to-install kit |
| Proof for the market | Tested to GOST 29151-91 |
Because the liner arrives as one welded piece, there is little welding work on site. The crew unfolds it, positions it in the pit or frame and fixes the edge.
III. The Project: Temporary Oil Storage Liners
The customer, located in a country neighboring Russia, needed liners for the temporary storage of crude oil, petroleum products and oily waste. The liners are designed for single use.
They are installed in two ways:
- On the bottom of an earthen storage pit.
- Inside a demountable frame tank, tied to the frame.
The liners are circular, from about 20 m to over 40 m in diameter, for storage volumes from 250 m³ to 1,000 m³.
We handled every step: producing the coated fabric, cutting and welding the liners, installing the hardware and packing each kit for shipment.
IV. Liner Material Specification
The liners use a PVC-coated polyester fabric with a PVDF-treated surface. Its specification:
| Property | Value |
|---|---|
| Base fabric | Polyester, 1000D × 1000D, 20 × 20 threads per inch |
| Coating | Oil-resistant and fuel-resistant PVC |
| Surface treatment | PVDF |
| Resistance | Crude oil, gasoline, lubricating oils and UV |
| Weight | ≥ 680 g/m² |
| Tensile strength (warp / weft) | 2730 / 1900 N/5cm |
| Tear strength (warp / weft) | 270 / 240 N |
| Peel (adhesion) strength | 90 N/5cm |
| Service temperature | −30 °C to +70 °C |
| Standard | Tested to GOST 29151-91 |
GOST 29151-91 is a Soviet-era standard for PVC-coated tarpaulin fabrics that is still in force, so we tested the material to it for this market.
V. Fabrication: Welding, Eyelets and Packing
A liner of this size is welded from many panels, and the seams decide whether it holds oil. The fabrication covers three things: the seams, the edge fixing and the shipping kit.
Triple Hot-Air Welded Seams
Each seam is hot-air welded with three weld lines. Seam strength is at least 90% of the base fabric strength.
Metal Eyelets Every 1.2 m
Metal eyelets run around the edge of each liner at 1.2 m spacing. Ropes pass through the eyelets to tie the liner to the hooks of the frame.
Complete Kits
Each liner ships as a complete kit:
- The welded liner.
- A set of fasteners.
- Ground anchors.
- A rack-type container for storage and transport.
The customer does not need to source parts locally. The kit arrives ready to deploy.
VI. What to Specify When Ordering an Oil Storage Liner
To quote a fuel containment liner, we need:
- The stored liquid: crude oil, diesel, gasoline, lubricants or oily waste.
- Contact time: single use, short term or long term.
- Role: primary storage or secondary containment.
- Size: diameter or dimensions, and storage volume.
- Installation: pit, frame tank or berm, and how the liner is fixed.
- Site temperature range. Our PVC-coated fabric is rated for −30 °C to +70 °C.
- Seam requirements: welding method and minimum seam strength.
- Test standards required by your market or project.
- Packing: kit contents and shipping container.
For more on welding methods, see our guide to PVC fabric welding.
VII. FAQ
What is meant by secondary containment?
Secondary containment is a second barrier that catches a liquid if its primary container leaks or fails. Examples are lined berms around tanks, dikes and spill pallets.
What are the two types of secondary containment?
Secondary containment is commonly divided into passive and active. Passive containment, such as a lined berm or dike, is in place all the time. Active containment, such as a spill kit or a deployable barrier, is put in place when a spill happens. US SPCC guidance also separates general secondary containment from specific, or sized, secondary containment.
What is primary and secondary containment?
Primary containment is the tank, pit liner or container that holds the liquid in normal use. Secondary containment is the backup barrier that catches the liquid if the primary containment leaks.